This study deals with analyzing the ventilation flow rate and temperature of the Jang-Sung Mining Corporation. It also predicts the flow rate and temperature at an altitude of -375 ML of the Back-San incline which is being constructed. The VnetPC program was mainly used to simulate amounts of air flow over the system. The temperature was simulated using the CLIMSIM program. The entire out-flow ventilation rate generated by the simulation (13,968 m3 / min) had an error of 10% compared with the actual quantity of the out-flow ventilation rate which was measured as 12,613 m3 / min. According to the result of the simulation, if the Back-San incline is used as an inflow opening, 3600 m3 / min of air would be exhausted and the temperature would be 30.65oC at an altitude of -375 ML. To improve ventilation efficiency, if the ductless fans utilized for face ventilation are connected with an air duct, 169 m3 / min of air would flow to the face.
본 연구에서는 국내에서 가장 깊은 심도를 가진 장성광업소를 대상으로 환기 평가와 온도에 대한 예측을 하였으며, 현재 준공중인 백산 사갱의 완공시의 -375 ML에서의 환기와 온도에 관하여 수치해석을 하였다. 주로 VnetPC를 이용하여 환기량 수치해석을 하였으며, CLIMSIM을 이용하여 온도에 관한 수치해석을 하였다. 연구 결과 장성광업소의 실재 총 배기량은 12613 M3/min 이였으며, VnetPC를 사용한 수치해석에서는 13968 M3/min로 산출되었으며, 이는 실제 배기량과 비교하였을 때 10%의 오차를 보이고 있으며, 비교적 정확한 결과가 산출되었다. -375 ML에서의 수치해석에서는 백산 사갱을 입기갱으로 사용할 때 3600 M3 / min의 배기량이 발생하였으며, -375 ML에서의 온도는 30.65oC로 산출되었다. 환기 개선을 위하여 막장 입구부의 국부선풍기에 풍관을 설치하였을 때의 수치해석 결과는 막장으로 공기량이 169 M3 / min가 입기 되었다.
References
Sorry, not available.
Click the PDF button.
Information
  • Publisher :The Korean Society of Mineral and Energy Resources Engineers
  • Publisher(Ko) :한국자원공학회
  • Journal Title :Journal of the Korean institute of mineral and energy resources engineers
  • Journal Title(Ko) :한국자원공학회지
  • Volume : 37
  • No :3
  • Pages :173-180