All Issue

2008 Vol.45, Issue 4 Preview Page
31 August 2008. pp. 326-336
Abstract
To simulate geothermal heat transport associated with the closed-loop geothermal heat pump (GHP) system, a numerical model named “Modified TOUGHREACT” is developed in this study. It can simulate temperature changes in the GHP system with circulating water through the pipe as well as it computes groundwater flow and aquifer temperature changes. The proposed model is based on TOUGHREACT, a widely accepted three-dimensional numerical simulator for heat and water flow and geochemical reactions in geothermal systems. To verify the model, simulation results are compared with the analytical solution of line source model and data set from an in-situ thermal response test. Simulation results are in very close agreement with both the analytical solution and field test data. The proposed model is used to analyze the sensitivities of design parameters that can affect the performance of the closed-loop GHP system. The most sensitive parameters on the system are the thermal conductivity of aquifer and the Darcian groundwater velocity considering acceptable distribution range in the realm of nature. Maximum change of the circulating fluid temperature at the outlet is about 4℃ when thermal conductivity of the aquifer changes from 2 W/m-K to 5 W/m-K and the Darcian groundwater velocity changes from 10-8 m/s to 10-6 m/s, respectively. The numerical model can be applied to the optimal design and the evaluation of long-term performance of the GHP system.
폐쇄형 지열 열펌프 시스템을 포함하는 지중 열 거동 양상을 정밀하게 시뮬레이션할 수 있는 수치 모델인 Modified TOUGHREACT를 개발하였다. 정밀한 계산을 위해 지하수의 흐름과 대수층의 온도 변화와 더불어 U-tube 내부를 흐르는 순환 유체의 온도 변화까지 반영할 수 있도록 하였다. 이 모델은 열 및 유체의 흐름과 지화학 반응 모의에 널리 사용되는 TOUGHREACT를 기반으로 하고 있고, 폐쇄형 지열 열펌프 시스템의 시뮬레이션에 적합하도록 수정 및 추가한 모듈을 검증하기 위해 선공급원 모델(line source model) 해석해와 현장 열 응답 시험 자료를 이용하였다. 해석해 결과와 열 응답 시험 자료 모두 시뮬레이션 결과와 잘 일치하였다. 검증된 모델을 사용하여 폐쇄형 지열 열펌프 시스템에 영향을 주는 변수들에 대한 민감도 분석을 실시하였다. 각 변수 값의 범위는 자연계에서 취득 가능한 범위로 설정하였고, 이 때 지중 열전도도와 지하수의 유속(Darcian velocity)이 지열펌프 시스템에 가장 큰 영향을 주는 변수들로 확인되었다. 지중 열전도도를 2 W/m-K에서 5 W/m-K로 변화시켰을 때와 지하수의 유속을 10-8 m/s에서 10-6 m/s로 변화시켰을 때, 출수구에서의 순환 유체의 온도 차이가 각각 4℃ 정도 발생하였다. 이 연구를 통해 개발한 수치 모델은 폐쇄형 지열 열펌프 시스템의 최적 설계와 장기적인 효율 예측에 활용될 수 있을 것이다.
References
  1. 심병완, 이영민, 김형찬, 송윤호, 2006, “지중 열교환기 효율 분석을 위한 지반내 열적・수리적 특성 조사”, 한국지구시스템공학회지, Vol. 43, No. 2, pp. 97-105.
  2. 차장환, 명대원, 구민호, 송윤호, 김형찬, 2007, “국내 암석의 암종별 열물성 특성 분석”, 한국신・재생에너지학회 2007년 추계학술대회 논문집, (사)한국신・재생에너지학회, 부산 해운대 그랜드호텔, 2007년 11월 6일~7일, pp. 493-496.
  3. 최항석, 이철호, 길후정, 최효범, 우상백, 2007, “수직 밀폐형 지중 열교환기용 뒤채움재의 열전도 및 점도특성 연구”, 한국신・재생에너지학회 2007년 추계학술대회 논문집, (사)한국신・재생에너지학회, 부산 해운대 그랜드호텔, 2007년 11월 6일~7일, pp. 529-532.
  4. Bennett and Myers, 1982, Momentum, heat, and mass transfer, Third ed., Wiley, New York. Carslaw, H. S. and Jaeger, J. C., 1959, Conduction of heat in solids, 2nd ed., Oxford Univers. Press, London.
  5. Edwards, A. L., 1972, TRUMP: A Computer Program for Transient and Steady State Temperature Distributions in Multidimensional Systems, National Technical Information Service, National Bureau of Standards, Springfield, VA.
  6. Fan, R., Jiang, Y., Yao, Y., Shiming, D., and Ma, Z., 2007, “A study on the performance of a geothermal heat exchanger under coupled heat conduction and groundwater advection”, Energy, Vol. 32, Issue 11, pp. 2199-2209.
  7. Freeze, R. A. and Cherry, J.A., 1979, Groundwater, Prentice Hall.
  8. Fujii, H., Itoi, R., and Ishikami, T., 2004, “Improvements on analytical modeling for vertical U-tube ground heat exchangers”, Geothermal Resources Council Transactions, Vol. 28, pp. 73-77.
  9. Fujii, H., Itoi, R., Fujii, J., and Uchida, Y., 2005, “Optimizing the design of large-scale ground-coupled heat pump systems using groundwater and heat transport modeling”, Geothermics, Vol. 34, pp. 347-364.
  10. Gaia Geothermal, 2006, The Ground Loop Design Version 3.0 User’s Manual.
  11. Gehlin, S. and Hellström, G., 2003, “Influence on thermal response test by groundwater flow in vertical fractures in hard rock”, Renewable Energy, Vol. 28, pp. 2221-2238.
  12. Hellström, G. and Sanner, B., 2000, EED: Earth Energy Designer User manual, Version 2.0.
  13. Narasimhan, T. N. and Witherspoon, P. A., 1976, “An Integrated Finite Difference Method for Analyzing Fluid Flow in Porous Media”, Water Resour. Res., Vol. 12, No. 1, pp. 57-64.
  14. Pruess, K., Oldenburg, C., and Moridis, G., 1999, TOUGH2 User’s Guide, Version 2.0.
  15. Rafferty, K., 2003, “Ground Water Issues in Geothermal Heat Pump Systems”, Ground Water, Vol. 41, Issue 4, pp. 408-410.
  16. Signorelli, S., Bassetti, S., Pahud, D., and Kohl, T., 2006, “Numerical evaluation of thermal response tests”, Geothermics, Vol. 36, pp. 141-166.
  17. Xu, T., Sonnenthal, E., Spycher, N., and Pruess, K., 2004, TOUGHREACT User’s Guide: A Simulation Program for Non-isothermal Multiphase Reactive Geochemical Transport in Variably Saturated Geologic Media.
Information
  • Publisher :The Korean Society of Mineral and Energy Resources Engineers
  • Publisher(Ko) :한국자원공학회
  • Journal Title :Journal of the Korean Society for Geosystem Engineering
  • Journal Title(Ko) :한국지구시스템공학회지
  • Volume : 45
  • No :4
  • Pages :326-336